Final | 4/3/2018 | 4/4/2018 | 4/4/2018 | A | PASS |
Rock A. Hudson
|
|
|
8724 garage code Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
|
Final | 4/2/2018 | 4/3/2018 | 4/3/2018 | A | FAIL |
Rock A. Hudson
|
|
|
Garage code 8724 Should be 87/1 Park Place Phone #: ###-#### Inspection requested via web by Darryn Coburn 110.3- Smoke detectors shall be wired as per instructions. No power to smokes. 210.52- Walls 24" or wider shall have a receptacle outlet installed. 30" wall in down bed shall be receptacle outlet installed. 314.16- Boxes shall be of an approved size for free conductor space. Box at end of peninsula 8 cu. in. with 11.25 cu. in. installed. 422.30- A means shall be provided to disconnect appliances from power. Hood and microwave. Lockout acceptable.
|
Rough-In Permanent Service | 1/3/2018 | 1/4/2018 | 1/4/2018 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn rough in ok p/s u/g n ok
|