Final | 8/14/2018 | 8/14/2018 | 8/14/2018 | P | PASS |
Tom Saunders
|
|
|
call for access if needed- Ron Phone #: ###-####...corrections made ok to final
|
Final | 8/7/2018 | 8/8/2018 | 8/8/2018 | A | FAIL |
Tom Saunders
|
|
|
entrance code 5151 enter Phone #: ###-#### Inspection requested via web by ron spen cer...
1..OCPD on oven is too large-manufacturers rating... 2..can trim in powder bath shower not damp location rated 3..outlets within 6ft of sink shall have GFCI protection-utillity rm
|
Rough-In Permanent Service | 1/16/2018 | 1/16/2018 | 1/16/2018 | P | PASS |
Tom Saunders
|
|
|
Ron Phone #: ###-####... rough ok to cover p/s u/g new ok contractor will provide ladder at time of final for access to furnace in attic to verify disconnect switch, light and service outlet
|
Rough-In Permanent Service | 1/15/2018 | 1/16/2018 | 1/16/2018 | A | FAIL |
Daryl DeGrange
|
|
|
Phone #: ###-#### Inspection requested via web by ron spen cer Install all reccessed cans at time of rough-in, install guard strips along NM with-in 6ft of attic access, Provide divider in chime box between line and low voltage, Staple NM along framing members as needed
|