Final | 3/21/2018 | 3/22/2018 | 3/22/2018 | P | PASS |
Rock A. Hudson
|
|
|
access code 3535 Phone #: ###-#### Inspection requested via web by Paula Gratiot Final ok
|
Final | 3/20/2018 | 3/21/2018 | 3/21/2018 | A | FAIL |
Rock A. Hudson
|
|
|
access code 3535 Phone #: ###-#### Inspection requested via web by Paula Gratiot 110.3- Devices shall be connected as per manufacurers instructions. Reverse polarity right of fireplace and receptacle in down bedroom not hot. 110.22- Breakers and disconnecting means for furnaces shall be identified as per which furnace each controls. 210.8- GFCI devices shall be installed in a readily accessible location. laundry behind washer not readiliy accessible. 210.52- A receptacle outlet shall serve wall space 2' of wider in master bedroom. Floor receptacle OK due to pocket door. 422.30- Microwave shall have a disconnecting means. Unable to locate breaker for microwave.
|
Rough-In Permanent Service | 1/17/2018 | 1/18/2018 | 1/18/2018 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Paula Gratiot Rough in ok p/s u/g n ok
|