Final | 4/19/2018 | 4/20/2018 | 4/20/2018 | A | PASS |
Rock A. Hudson
|
|
|
code 4224 any ? call bill ###-#### Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
Final | 4/18/2018 | 4/19/2018 | 4/19/2018 | A | FAIL |
Rock A. Hudson
|
|
|
CODE 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn 210.52(C)- KItchen receptacle shall be located so that no point measured along wall line is more than 24" from a receptacle. 314.16- Boxes shall have sufficient size for free air space. Hood 10 cu in with 7.5 1 1/2" deep box.
|
Rough-In Permanent Service | 2/14/2018 | 2/15/2018 | 2/15/2018 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn rough in ok p/s u/g n ok
|