Final | 9/19/2018 | 9/20/2018 | 9/20/2018 | A | PASS |
James Ady
|
|
|
Tobias is the site contact. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker Core and Shell only Final ok.
|
Permanent Service | 8/16/2018 | 8/17/2018 | 8/17/2018 | A | PASS |
James Ady
|
|
|
Tobias is the site contact. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker testing done p/s u/g n ok
|
Permanent Service | 8/15/2018 | 8/15/2018 | 8/15/2018 | P | FAIL |
James Ady
|
|
|
Tobias is the contact. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker 230.95C Proformance testing required
|
Electrical Rough-In | 7/31/2018 | 8/1/2018 | 8/1/2018 | P | PASS |
James Ady
|
|
|
We need cover inspection. Tobias is the site contact. Thank you Phone #: ###-#### Inspection requested via web by Stacie Tasker Soffits along front of building only ok to cover
|
Electrical Rough-In | 7/11/2018 | 7/12/2018 | 7/12/2018 | A | CANC |
James Ady
|
|
|
We need an underground inspection. Jeff is the site contact. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker Bar XL to pull permit for site lighting will inspect on that permit
|
Electrical Rough-In | 6/21/2018 | 6/22/2018 | 6/21/2018 | A | CANC |
James Ady
|
|
|
We need an underground inspection for SITE at Bldg A. Tobias is the site contact. Thank you! Phone #: ###-#### >> Inspection requested via web by Stacie Tasker Inspection cancelled from web by: Stacie Tasker
|
Electrical Rough-In | 6/19/2018 | 6/20/2018 | 6/20/2018 | A | PASS |
Daryl DeGrange
|
|
|
We need an underground inspection.Thank you Tobias is the site contact. Phone #: ###-#### Inspection requested via web by Stacie Tasker Rough-in ok cover underground, under westside pourback
|
Electrical Rough-In | 6/15/2018 | 6/15/2018 | 6/15/2018 | P | PASS |
James Ady
|
|
|
We need an underground inspection. Tobias is the site contact. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker remaining perimeter underground ok to cover
|
Electrical Rough-In | 6/13/2018 | 6/14/2018 | 6/14/2018 | A | PART |
James Ady
|
|
|
We need an underground inspection. Tobias is the site contact. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker Underground along exterior wall only ok to cover
|
Electrical Rough-In | 5/17/2018 | 5/18/2018 | 5/18/2018 | A | PASS |
James Ady
|
|
|
We need a ufer inspection, please. Dave is the site contact. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker ufer only ok
|
Electrical Rough-In | 3/12/2018 | 3/12/2018 | 3/12/2018 | P | PASS |
James Ady
|
|
|
WE need an underground at bldg A. Phone #: ###-#### Inspection requested via web by Stacie Tasker underground only ok to cover
|