Final | 2/1/2019 | 2/1/2019 | 2/1/2019 | P | PASS |
James Ady
|
|
|
Please call for access Phone #: ###-#### Inspection requested via web by John VanZandt Corrections made final ok
|
Final | 1/30/2019 | 1/31/2019 | 1/31/2019 | A | FAIL |
Rock A. Hudson
|
|
|
Please call for access Phone #: ###-#### Inspection requested via web by John VanZandt 210.8(A)(1)- All receptacles installed to serve bathroom basins shall have GFCI protection. All basement bathroom receptacles. 210.8(A)(2)- All 15 and 20 amp 120 volt receptacle outlets installed in a garage shall have GFCI protection. Receptacle located on warm wall. 210.52(C)- In kitchens, pantries, and similar areas receptacle outlets installed to serve counter top surfaces shall be installed so no point measured along wall line is more than 24" from a receptacle. 250.122- Minimum equipment grounding conductor for a 30 amp circuit shall not be smaller than #10. #12 installed in AC whip.
|
Electrical Rough-In | 8/27/2018 | 8/27/2018 | 8/27/2018 | P | PASS |
Rock A. Hudson
|
|
|
Floor heat Insp Phone #: ###-#### Inspection requested via web by John VanZandt Rough in ok cover
|
Rough-In Permanent Service | 2/28/2018 | 3/1/2018 | 3/1/2018 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt Class 2 used for pull wire, no changes to each side of fire place, receptacles in pantry are GFCI devices for wire mold. Rough in ok cover p/s u/g n ok
|
Rough-In Permanent Service | 2/27/2018 | 2/28/2018 | 2/28/2018 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt 110.3- As per manufacturers instructions furnace shall have a minimum of 12 ga branch circuit. 210.52(A)(2)- Cabinet spec not found. Possible wall space each side of fireplace. 210.52(C)(1)- If receptacle located in pantry serve counter top space no point on counter shall be more than 24" from a receptacle. 300.15- Master bath stool fan not made up. 300.3- 600 volt and class 2 in same box for floor heat. Both shall have rating to cover voltage present in box. 408.3(A)(2)- Service conductor terminations shall have barriers installed. * Meter load terminations shall be lower lugs. Upper for incoming conductors.
|