Permit Information
Permit NumberELE18-00900
StatusFinaled
Name CRAIGS ELECTRIC SERVICE
Site Address 3701 W CRESCENT RIM DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration: Swimming pool remodel
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/16/20187/17/20187/17/2018PPASS
DetailsJames Ady
If you can call me with 20-30 minutes notice I can meet you there.Thanks Phone #: ###-#### Inspection requested via web by Craig Korell final ok
Electrical Rough-In6/6/20186/7/20186/7/2018PPASS
DetailsRock A. Hudson
Trench in back is ready. Please call Stan when you arrive.Stan-###-#### Phone #: ###-#### Inspection requested via web by Craig Korell
Underground rough in ok cover
Electrical Rough-In6/6/20186/6/20186/6/2018PNH
DetailsRock A. Hudson
This Inspection will be for the underground leading into the building from the pool. Thank you. Phone #: ###-#### Inspection requested via web by Craig Korell
All gates locked contact unable to reach responcible party for access. Will recall
Electrical Rough-In5/13/20185/14/20185/14/2018APASS
DetailsRock A. Hudson
Equipotential bonding grid ready for inspection. Access is around right side of condos. Stan is manager-###-#### Phone #: ###-#### Inspection requested via web by Craig Korell
Perimeter and luminaire shell bond rough in ok cover
Electrical Rough-In3/14/20183/15/20183/15/2018APASS
DetailsRock A. Hudson
This inspection is for the equipotential bonding plane. The gate on the right side of the apartment complex will be unlocked. If it is not here is the phone number to the manager Stan. ###-####. Phone #: ###-#### Inspection requested via web by Craig Korell
Will be future inspection for luminaires and existing pool shell where rebar has been exposed and run back to equipment with underground conduits. Inspection for top 6" extension pour rebar on 4 corners stubs only rough in ok cover
Conference3/9/20183/14/20183/14/2018ADONE
DetailsRock A. Hudson
I will be on site by 8:30 am. Feel free to call me when you are on your way and I will meet you at the front door. Phone #: ###-#### Inspection requested via web by Craig Korell
Discussed the requirements for pool remodel. Pool shell bonding will be bonded to exposed rebar and then rebar will be encased in new concrete pour. 6" of concrete to be added to top of pool shell with seperate bond needed due to this rebar not connected to existing. Equipotential perimeter bond and new LED luminaires to be installed in existing luminaire shells. Bonding and potting inspections required for lighting. All pool equipment to be GFCI protected.