Final | 9/7/2018 | 9/7/2018 | 9/7/2018 | P | PASS |
Tom Saunders
|
|
|
key in front weatherproof cover Phone #: ###-#### Inspection requested via web by Alan Lusk...corrections made...ok to final
|
Final | 9/6/2018 | 9/6/2018 | 9/6/2018 | P | FAIL |
Tom Saunders
|
|
|
Key is in front weatherproof cover Phone #: ###-#### Inspection requested via web by Alan Lusk.... 1..microwave outlet needs installed 2..outlets need completed-back of pennisula 3..breaker lock outs need installed on hardwired appliances-dishwasher and hood 4..panel shall be labelled completely and legiable-twin breakers not labelled 5..garage circuit shall have outlet per parking space-only one outlet found
|
Electrical Rough-In | 5/22/2018 | 5/23/2018 | 5/23/2018 | P | PASS |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Whole house rough-in ok to cover
|
Permanent Service | 3/28/2018 | 3/28/2018 | 3/28/2018 | P | PASS |
Eric Story
|
|
|
Need service inspection after fire. House to be rewired soon. Lock box code 2326. Phone #: ###-#### Inspection requested via web by Alan Lusk p/s o/h rec ok
|
Permanent Service | 3/28/2018 | 3/28/2018 | 3/28/2018 | P | CANC |
Eric Story
|
|
|
Need service inspection to re energizer after fire. House to be re wired at a later date. Phone #: ###-#### >> Inspection requested via web by Alan Lusk Inspection cancelled from web by: Alan Lusk
|