ELE-Aging Inspection | 6/15/2020 | 6/15/2020 | 6/15/2020 | | PASS |
Daryl DeGrange
|
|
|
See Doc-expire
|
DOC - Permit Expired | 6/15/2020 | 6/15/2020 | 6/15/2020 | P | PASS |
Daryl DeGrange
|
|
|
Contact number no longer good. No activity within 180 days. This permit is expired. A new permit is required to complete this job.
|
Permanent Service | 6/11/2018 | 6/12/2018 | 6/12/2018 | A | PASS |
Eric Story
|
|
|
Overhead service change. Call Ryan for lock box number. Phone #: ###-#### Inspection requested via web by Ryan Schaffer p/s o/h rec ok
|
Permanent Service | 5/16/2018 | 5/17/2018 | 5/17/2018 | A | FAIL |
Eric Story
|
|
|
Power has been off for over 1 year. Need inspection so Idaho Power can turn power on. Call Ryan for lock box code ###-#### Phone #: ###-#### Inspection requested via web by Ryan Schaffer Updated grounding electrode system required for service Must maintain 36" in front of electrical equipment No more then 6 throws of the hand on main breaker side of split bus panel No more then 18" of unfused conductors allowed in a structure
|