Permit Information
Permit NumberELE18-02598
StatusFinaled
Name BOISE BASIN ELECTRIC
Site Address 6829 E WARM SPRINGS AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/13/20189/13/20189/13/2018PPASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
Final9/12/20189/12/20189/12/2018PFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Alan Lusk
110.3- Items shall be connected as per manufacturers instructions. Level 3 bath GFI has reverse polarity, Level 1 understair light not working.
210.8- Washer receptacle is located with in 6' of a sink and shall be GFCI protected.
210.12- Level 1 room has closet with clothes rod installed so shall have AFCI protected.
314.20- Where boxes installed in a wall with non combustible materials they shall not be set back more than 1/4" from surface with out box extensions installed. Kitchen counter receptacles.
348.30- FMC shall be secured with in 12" of each box. Disposal
Rough-In Permanent Service7/12/20187/12/20187/12/2018PPASS
DetailsJames Ady
garage code 1001e Phone #: ###-#### Inspection requested via web by Alan Lusk rough in ok p/s u/g n ok
Electrical Rough-In7/11/20187/12/20187/12/2018ACANC
DetailsJames Ady
garage code 1001e Phone #: ###-#### Inspection requested via web by Alan Lusk
Final7/12/20187/12/20187/12/2018PCANC
DetailsJames Ady
garage code 1001e Phone #: ###-#### Inspection requested via web by Alan Lusk