Final | 11/8/2018 | 11/8/2018 | 11/8/2018 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
Final | 11/7/2018 | 11/7/2018 | 11/7/2018 | A | FAIL |
Rock A. Hudson
|
|
|
GARAGE CODE 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn 300.15- All NM cables shall terminate in a box. Level 1 TV location wire stubbed back in wall. Need a box and cover.
|
Rough-In Permanent Service | 8/20/2018 | 8/21/2018 | 8/21/2018 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
|
Rough-In Permanent Service | 8/16/2018 | 8/17/2018 | 8/17/2018 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn 300.4- Where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected form physical damage. Understairand nook. 314.25- Recessed junction box cover shall be installed as per instructions. Out master entrance. 334.12-NM cable shall not be installed where subject to physical damage. Above drywall stop on stairs and in front of stud in laundry rm. Fan S/L and travellers. 350.30- LFMC shall be secured in place with in 12" of termination of a box and fireplace.
|