Final | 8/27/2018 | 8/28/2018 | 8/28/2018 | P | NR |
Tom Saunders
|
|
|
Late afternoon if possible Phone #: ###-#### Inspection requested via web by Same Electric...windows within 5ft of tub waterline shall be tempered, light within 5ft of tub shall be nonmettalic and GFCI protected, metal gazebo shall be bonded to hot tub, and load calculation on 100A panel is required to approve addition of 40A hot tub breaker on bussing
|
Electrical Rough-In | 8/28/2018 | 8/28/2018 | 8/28/2018 | P | PASS |
Tom Saunders
|
|
|
Late afternoon if possible Phone #: ###-#### Inspection requested via web by Same Electric...8/3 romex thru attic for 40A hot tub circuit...GFCI protected disconnect...pvc ran to tub...underground correct depth ok to cover
|