Final | 8/3/2020 | 8/4/2020 | 8/4/2020 | P | FAIL |
Mark Moncarr
|
|
|
ok with vidoe/photo // Gavin Phone #: ###-#### 1. Tamper resistant recepts needed in down hall, both down baths, and bed on NE corner main level. 2. Straps needed for EMT for lighting in bed on W side main level. 3. Verif;y depth of 2 runs of 1/2 pvc in backyard. 4. Also need to verify vanit;y height in bath NE corner. Recept cannot be lower than 12in from top of sink countertop.
|
Electrical Rough-In | 9/13/2018 | 9/14/2018 | 9/14/2018 | A | PASS |
Mark Moncarr
|
|
|
Gavin Phone #: ###-#### Ok cover. All metal boxes have ground screws installed and neutrals identified as current carrying.
|
Conference | 9/4/2018 | 9/4/2018 | 9/4/2018 | P | DONE |
Mark Moncarr
|
|
|
Call half hour before Jennifer Phone #: ###-#### Discussed outlet and lighting requirements for 2 baths, hall and kitchen. Also discussed possibility of battery powered smoke detectors. Walls and ceilings will not be opened up for accessibility.
|
Final | 8/13/2020 | 8/14/2020 | | A | |
Mark Moncarr
|
|
|
Gavin - */Virtual Inspection Requested*/ Phone #: ###-####
|