Information based on query as of Friday, June 28, 2024.
Permit Information
Permit NumberELE18-04099
StatusFinaled
Name TDR ELECTRIC
Site Address 4216 E PARKCENTER BLVD
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: new
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/10/20191/10/20191/10/2019PPASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
Rough-In Permanent Service10/25/201810/25/201810/25/2018APASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Therrin Robertson
Rough in ok cover p/s u/g n ok
Rough-In Permanent Service10/24/201810/24/201810/24/2018AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Therrin Robertson
225.31- A disconnecting means shall be provided for seperate garage structure on exterior or where conductors enter structure.
300.4- Nail plates shall be installed where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface.
300.4(B)(1)- NM cables shall be protected from damage where they enter an enclosure. Connectors shall be installed as per manufacturers instructions. Connectors not completely installed at front outdoor receptacle box, both junction boxes for garage wiring at house nad garage, service.
314.25- Recessed can junction box shall be installed to totally cover opening in box. Can at top of stair back cover partially off.
352.46- Where UF cable enters or emerges from PVC conduit it shall be protected from damage by a bushing.
408.7- Unused breaker openings shall be closed.