Final | 3/18/2019 | 3/19/2019 | 3/19/2019 | A | PASS |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI Corrections fixed final ok
|
Final | 2/21/2019 | 2/22/2019 | 2/22/2019 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI 210.52(A)- No point measured along floor line shall be more than 6' from a receptacle outlet, in up be 4' wall. 410.10(A)- Provide proof of tub and shower trim and lamp wet location rated. 410.16- Luminaires located in clothes closets shall have totally enclosed lamps. * Do not call for reinspection until stair and upstair rails in place. * No access to 2 of 3 garage areas.
|
Rough-In Permanent Service | 10/24/2018 | 10/25/2018 | 10/25/2018 | A | PASS |
Mark Moncarr
|
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI p/s u/g n ok
|