Information based on query as of Thursday, June 20, 2024.
Permit Information
Permit NumberELE18-04213
StatusFinaled
Name ROBERTSON ELECTRIC
Site Address 3752 S HARRIS RANCH AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: Complete wiring of a single family home
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/12/20193/13/20193/13/2019APASS
DetailsJames Ady
Garage code is 7352 enter Phone #: ###-#### Inspection requested via web by Zane Robertson corrections made final ok
Final3/11/20193/12/20193/12/2019AFAIL
DetailsJames Ady
Garage code is 7352 enter Phone #: ###-#### Inspection requested via web by Zane Robertson 314.25 Devices shall have covers(Opener receps) 422.31Appliances shall have Disc.(Both ovens, Dish/disp) 110.22 Disconect shall be identified(Furnace Disc) Install gfci recep in landscape bell box. Wire A/C.
Final3/6/20193/7/20193/7/2019ACANC
DetailsRock A. Hudson
Garage code is 7352 Phone #: ###-#### >> Inspection requested via web by Zane Robertson Inspection cancelled from web by: Zane Robertson
Rough-In Permanent Service12/13/201812/14/201812/14/2018APASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Zane Robertson corrections made rough in ok p/s u/g n ok
Rough-In Permanent Service12/12/201812/13/201812/13/2018AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Zane Robertson
300.4- Where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected from physical damage by nail plates. Above master bath switches.
300.5(H)- Where cable emerges from grade from a underground conduit they shall be prtected from damage by bushings. UF in family and kitchen.
314.25- All boxes shall have covers. Above master utility in shall part of attic.
* Unable to locate AC branch circuit located at back of garage.
Electrical Rough-In11/1/201811/2/201811/2/2018PPASS
DetailsJames Ady
Under ground for floor plug and island Phone #: ###-#### Inspection requested via web by Zane Robertson Underground only ok to cover