Permit NumberELE18-04217
StatusFinaled
Name TOTAL PRECISION ELECTRIC LLC
Site Address 1974 S EAGLESON RD
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: New residential construction
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/23/20191/24/20191/24/2019APASS
DetailsEric Story
Phone #: ###-#### Inspection requested via web by Tyler Ridley
Final ok
Final1/22/20191/23/20191/23/2019AFAIL
DetailsEric Story
Phone #: ###-#### Inspection requested via web by Tyler Ridley
210.52 All basins shall have a receptacle located within 36"
210.52 Wall spacing shall be 6' from a cabinet in kitchen, counter receptacles do not count for wall spacing
406 tamper resistant in pantry
Electrical Rough-In11/3/201811/5/201811/5/2018APASS
DetailsEric Story
Phone #: ###-#### Inspection requested via web by Tyler Ridley
Corrections fixed
Rough-in ok to cover
Permanent Service11/5/201811/5/201811/5/2018PPASS
DetailsEric Story
Phone #: ###-#### Inspection requested via web by Tyler Ridley

p/s u/g n ok
Electrical Rough-In11/2/201811/2/201811/2/2018AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Tyler Ridley
110.3(A)- Boxes installed shall be listed. Allied pancake boxes provide listing or replace.
110.3(B)- Acorn clamp shall be installed as per manufacturers instructions. Grounding electrode conductor shall be installed opposite of set screw.
300.4- Several nail plates needed through out. Garage out lights, master bed corner, master hall, fire place left side, entry, pantry switch, utility. 334.12- NM cable shall not be installed where subject to physical damage. Utility switch leg out of wall below ceiling and pulled tight.
408.3(A)(2)- Barriers shall be in place where service conductors terminate in panel.