Final | 7/10/2019 | 7/11/2019 | 7/11/2019 | A | PASS |
Mark Moncarr
|
|
|
Corrections made ready for inspection Phone #: ###-#### Inspection requested via web by Kevin Oderkirk Ok final. Corrections made.
|
Final | 7/9/2019 | 7/10/2019 | 7/10/2019 | A | FAIL |
Mark Moncarr
|
|
|
Should be open all day if not call me thanks Phone #: ###-#### Inspection requested via web by Kevin Oderkirk 1. Grocery counter recept needs to be removed and blanked. You cannot extend of bath GFI. 2. GFI needed in washer outlet. 3. Recept needed below 3 gang in mstr bed just before entry to bath. 2 ft wall space. 4. 2 recepts needed in dining above cabinet. 210.52.
|
Electrical Rough-In | 4/24/2019 | 4/25/2019 | 4/25/2019 | A | PASS |
Mark Moncarr
|
|
|
Bathroom floor heat ready for cover inspection key will be in front door master bath, and basement bath has the floor heat thanks Phone #: ###-#### Inspection requested via web by Kevin Oderkirk Ok cover flr heat mstr and basement bath.
|
Electrical Rough-In | 12/14/2018 | 12/14/2018 | 12/14/2018 | P | PASS |
James Ady
|
|
|
Inspection requested via web by Kevin Oderkirk rough in ok
|
Permanent Service | 11/12/2018 | 11/13/2018 | 11/13/2018 | A | PASS |
James Ady
|
|
|
Ready for permanent service now thanks Phone #: ###-#### Inspection requested via web by Kevin Oderkirk p/s u/g n ok
|
Permanent Service | 11/9/2018 | 11/9/2018 | 11/9/2018 | P | FAIL |
James Ady
|
|
|
Inspection requested via web by Kevin Oderkirk 230.6 Unfused conductors shall be outside the building. 250.66 Grounding electrode system shall be installed
|