Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberELE19-00038
StatusFinaled
Name BOISE ELECTRIC SERVICES
Site Address 2028 N 16TH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: New electrical for kitchen, two bathrooms, dinning and living spaces. New Sub panel.
grounding as needed.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/10/20194/10/20194/10/2019PPASS
DetailsMark Moncarr
Phone #: ###-#### Inspection requested via web by Garrett Collins Ok final.
Final4/8/20194/9/20194/9/2019PNR
DetailsMark Moncarr
Phone #: ###-#### Inspection requested via web by Garrett Collins
Electrical Rough-In1/10/20191/11/20191/11/2019APASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Garrett Collins
Rough in ok cover
Electrical Rough-In1/9/20191/10/20191/10/2019PFAIL
DetailsRock A. Hudson
Elec ri. Zach on site. Phone #: ###-#### Inspection requested via web by Garrett Collins 210.52- A receptacle outlet shall be installed with in 6' of pocket door in master bedroom.
300.4- Where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected from damage by nail plates in kitchen near sink.
314.17(C)- Where knob and tube wiring enter a non-metallic box the conductors shall enter thru individual holes. Kitchen ceiling near door.
334.30- NM calbe shall be secured in place with in 12" of a box. NM cable passes thru hole in beam and enters recessed can with out being secured in place.
House is unoccupied