Information based on query as of Tuesday, July 16, 2024.
Permit Information
Permit NumberELE19-00093
StatusFinaled
Name GLENN ELECTRIC
Site Address 3811 S ECKERT RD
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: ROUGH & PERM SERVICE
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/8/20194/8/20194/8/2019PPASS
DetailsJames Ady
GARAGE CODE 4224 OR 10020

THANK YOU Phone #: ###-#### Inspection requested via web by Bob Glenn corrections made final ok
Final4/5/20194/8/20194/8/2019AFAIL
DetailsRock A. Hudson
garage code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn
300.15- At each outlet point NM cable shall terminate in a box. Above fireplace 14-2 left in wall shall terminate in a box.
314,17(B)- Where NM cable enters a box the jacket shall enter box 1/4" [ast clamp minimum in level 1 bathroom receptacle.
422.31- Hard wired range hood shall have a disconnecting means. Lock out is acceptable as per 110.25.
Rough-In Permanent Service1/8/20191/9/20191/9/2019APASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Bob Glenn
Rough in ok cover p/s u/g n ok