Final | 3/11/2019 | 3/11/2019 | 3/11/2019 | P | PASS |
Tom Saunders
|
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt... corrections made...ok to final
|
Final | 3/7/2019 | 3/8/2019 | 3/8/2019 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt 210.52(C)- Pantry counter top area shall have receptacle outlets installed so that no point measured along wall line horizontally is more than 24" from a receptacle outlet.
|
Rough-In Permanent Service | 1/17/2019 | 1/18/2019 | 1/18/2019 | A | PASS |
Tom Saunders
|
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt... rough ok to cover p/s u/g new ok
|