Final | 4/22/2019 | 4/23/2019 | 4/23/2019 | A | PASS |
Tom Saunders
|
|
|
No one lives in the home. Garage man door will be left open for your access. Inspector can access all electrical work via the man door entrance. Please give Same Day Electric a call when you are on the way 208.377.3278. Chris is the electrician 340.7806. Inspection requested via web by Same Electric... corrections made...ok to final
|
Final | 4/12/2019 | 4/12/2019 | 4/12/2019 | P | FAIL |
Tom Saunders
|
|
|
House is vacant and is for sale-lockbox code is 5260 on front door Phone #: ###-#### Inspection requested via web by Same Electric... no access no code lock box could be located also will need access to attic space..ladder required at time of inspection
|
Final | 4/5/2019 | 4/5/2019 | 4/5/2019 | P | FAIL |
Tom Saunders
|
|
|
House is vacant and is for sale-lockbox code is 5260 on front door Phone #: ###-#### Inspection requested via web by Same Electric... 1) outlet and light needed at attic fan location..210.70(C) 2) all openings in panels/load centers shall be closed...no code violation shall be retained...furnace load center needs a blank 3) clearances for main panel need addressed...3ft in front and 30" side...cabinet needs addressed around panel
|