Final | 8/26/2019 | 8/27/2019 | 8/27/2019 | A | PASS |
Tom Saunders
|
|
|
Phone #: ###-#### Inspection requested via web by Steve Blackmer...corrections made...ok to final
|
Final | 8/23/2019 | 8/26/2019 | 8/26/2019 | A | FAIL |
Tom Saunders
|
|
|
Final For Remodel and Addition/ The owners Son will be home to allow access. Thank You Phone #: ###-#### Inspection requested via web by Steve Blackmer... 1) lockouts need installed on hardwired appliances..range and hood 2) NM wire exposed to physical damage..island outlets 3) bath outlets are double GFCI protected 4) laundry exhaust fan needs addressed
|
Electrical Rough-In | 5/8/2019 | 5/9/2019 | 5/9/2019 | A | PASS |
Eric Story
|
|
|
Wall cover for Addition, Still have interior fishing work to do on existing side of structure. Contact Greg ###-#### Thank You Phone #: ###-#### Inspection requested via web by Steve Blackmer. Additional staples will be installed Wednesday. Thank You Phone #: ###-#### Inspection requested via web by Steve Blackmer corrections fixed Addition ok to cover and remodeled area for living and kitchen ok
|
Electrical Rough-In | 5/8/2019 | 5/8/2019 | 5/8/2019 | A | FAIL |
Eric Story
|
|
|
Wall cover for Addition, Still have interior fishing work to do on existing side of structure. Contact Greg ###-#### Thank You Phone #: ###-#### Inspection requested via web by Steve Blackmer 334.30 Securing of MN cable shall not be greater then 12" of and clamped box and not more then 8" of a non clamping type boxe.... throughout whole addition
|
Permanent Service | 5/3/2019 | 5/6/2019 | 5/6/2019 | P | PASS |
Rock A. Hudson
|
|
|
New Service and 200A interior panel associated with remodel/Addition, Contact Greg ###-#### Phone #: ###-#### Inspection requested via web by Steve Blackmer p/s o/h rec ok
|
Permanent Service | 5/3/2019 | 5/3/2019 | 5/3/2019 | P | CANC |
Tom Saunders
|
|
|
Replace service and interior 200A panel associated with Remodel/ Addition. contact Greg ###-####. Thank You Phone #: ###-#### >> Inspection requested via web by Steve Blackmer Inspection cancelled from web by: Steve Blackmer
|