Final | 10/14/2019 | 10/14/2019 | 10/14/2019 | P | PASS |
James Ady
|
|
|
Garage 0243 Phone #: ###-#### Inspection requested via web by Heath Thomas Corrections made Final ok
|
Final | 10/10/2019 | 10/11/2019 | 10/11/2019 | P | FAIL |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Heath Thomas 440.6 Max overcurrent shall not exceed nameplate.(A/C is 45A max 50A installed.) 314.20. Boxes shall have extendor rings if set back more than 1/4in.(Spark rings needed in back splash) Hood needs wired
|
Rough-In Permanent Service | 6/3/2019 | 6/4/2019 | 6/4/2019 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Heath Thomas Corrections made rough in ok p/s u/g n ok
|
Rough-In Permanent Service | 5/31/2019 | 6/3/2019 | 6/3/2019 | A | FAIL |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Heath Thomas 300.4A1. Nail plates needed where SE cable enters from crawl to attic
|
Electrical Rough-In | 5/7/2019 | 5/8/2019 | 5/8/2019 | A | PASS |
James Ady
|
|
|
Exterior eaves and soffits for cover. Recessed can lights with fire rated "hats". Phone #: ###-#### Inspection requested via web by Heath Thomas Soffits only ok to cover
|