Permit Information
Permit NumberELE19-02028
StatusFinaled
Name ENERGY ENTERPRISE GROUP LLC
Site Address 1290 W MYRTLE ST Unit: 400
Project Name 
Customer Number761
ePlanReviewNo
Description
Alteration: Provide new LED lighting and power receptacles for new tenant .
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final11/7/201911/8/201911/8/2019APASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Kerri Hamilton

No card posted. Final ok
Electrical Rough-In8/27/20198/27/20198/27/2019PCANC
DetailsRock A. Hudson
Please call 30 mins prior Phone #: ###-#### >> Inspection requested via web by Kerri Hamilton Inspection cancelled from web by: Kerri Hamilton
Final8/20/20198/21/20198/21/2019PPART
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
Listings confirmed on furniture whips. All receptacles checked except floor receptacles.
TCO to install furniture only OK
Electrical Rough-In8/16/20198/19/20198/19/2019APASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
Grid complete. Rough in ok cover
Electrical Rough-In8/16/20198/16/20198/16/2019AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
330.30- MC shall be sucred with in 12" of a box. jumpers between boxes and fixture whip exceeding 6'
Electrical Rough-In8/15/20198/15/20198/15/2019PFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
330.30- MC shall be secured with in 12" of a box, not including fixture whips.
* Popped MC in S,E, office still not repaired. Reception/ lobby area being grouted at time of inspection. Recall when accessible.
Electrical Rough-In8/13/20198/13/20198/13/2019PPASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
South offices and south hall grid rough in ok cover.
Electrical Rough-In8/6/20198/6/20198/6/2019PPASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
Popped MC S.E. AT PERLIN STRAP.
403 thru 412 grid rough in ok cover
Electrical Rough-In6/28/20196/28/20196/28/2019PPASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Reception and break room soffits only ok to cover
Electrical Rough-In6/5/20196/6/20196/6/2019PPASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
Confirmed required receptacles for meeting rooms only 1 large enough for floor receptacles and it needs 2. Walls rough in ok cover