Permit Information
Permit NumberELE19-02323
StatusFinaled
Name TDR ELECTRIC
Site Address 4329 E PARKCENTER BLVD
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: new
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/17/20199/17/20199/17/2019APASS
DetailsJames Ady
garage code 1957 Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
Final9/17/20199/17/20199/17/2019ACANC
DetailsJames Ady
Garage Code 1957 Phone #: ###-#### >> Inspection requested via web by Therrin Robertson Inspection cancelled from web by: Therrin Robertson
Rough-In Permanent Service7/11/20197/11/20197/11/2019PPASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Therrin Robertson Corrections made rough in ok p/s u/g n ok
Rough-In Permanent Service7/10/20197/10/20197/10/2019AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Therrin Robertson
110.3- Expansion joint shall be installed as per manufacturers instructions. At time of install joint shall be opened to mid point to allow for expansion and contraction.
110.14- Connection to concrete encased electode shall be tight. moved with fingers.
250.148- Metal boxes shall be connected to equipment grounding conductors. All equipment grounding conductors in a box shall be connected together. Complete make up.
300.15- All NM cables shall terminate in a box. Up bed smoke detector.
312.5(A)- Unused openings in meter base shall be closed by approved means. 2" KO open.
590.6(B)- Temp power receptacles other than 120 volt shall have GFCI protection. 250 in temp pole failed test.