Final | 7/23/2019 | 7/24/2019 | 7/24/2019 | A | PASS |
James Ady
|
|
|
Please call Juan with any questions Phone #: ###-#### Inspection requested via web by William Salts Final ok
|
Electrical Rough-In | 7/9/2019 | 7/10/2019 | 7/10/2019 | A | PASS |
Rock A. Hudson
|
|
|
Please call Juan with any questions Phone #: ###-#### Inspection requested via web by William Salts Rough in ok cover
|
Electrical Rough-In | 7/8/2019 | 7/9/2019 | 7/9/2019 | A | FAIL |
James Ady
|
|
|
Please call Juan with any questions Phone #: ###-#### Inspection requested via web by William Salts No answer amilbox not set up. 110.3B Listed equipment shall be installed as per manufacturer instructions. (2 gang nail on in kitchen. Use a listed screw on box) 300.4A1. Cables through bored holes less than 1 1/4in from face of stud shall be protected. BCC Section 9-05-32 Violations shall not be retained>
|
Final | 7/8/2019 | 7/8/2019 | 7/8/2019 | P | NR |
James Ady
|
|
|
Please call Juan with any questions, as close to the end of the day as possible Phone #: ###-#### Inspection requested via web by William Salts NR recall for AM
|