Permit Information
Permit NumberELE19-03082
StatusFinaled
Name NEW LEAF ELECTRIC
Site Address 503 N MEADOWLAND DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Addition: Adding a circuit to provide power for a new shed. Trenching from meter box to shed, and wiring inside with light and receptacles.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/24/20198/26/20198/26/2019APASS
DetailsRock A. Hudson
Corrections have been made since last inspection. Phone #: ###-#### Inspection requested via web by Dan Hilke
Final ok
Final8/17/20198/19/20198/19/2019AFAIL
DetailsTom Saunders
Homeowner said he would be there. Trench is still open, and wiring inside is not going to get covered. GFCI Bkr in meterbox, #12 THHN in conduit to shed, and 12-2 MC inside with metal boxes that have gnd pigtails. Give me a call if there''s any questions. Phone #: ###-#### Inspection requested via web by Dan Hilke...
1..accessory building shall have luminaire on exterior...210.70(2)(2)
2..disconnect needs installed...225.31
Electrical Rough-In8/19/20198/19/20198/19/2019APASS
DetailsTom Saunders
Homeowner said he would be there. Trench is still open, and wiring inside is not going to get covered. GFCI Bkr in meterbox, #12 THHN in conduit to shed, and 12-2 MC inside with metal boxes that have gnd pigtails. Give me a call if there''s any questions. Phone #: ###-#### Inspection requested via web by Dan Hilke....
trench ok to cover
interior rough in ok