Permit Information
Permit NumberELE19-03179
StatusFinaled
Name B & J ELECTRIC INC
Site Address 3510 E VIA ESTANCIA LN
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: New home
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/16/20204/16/20204/16/2020PPASS
DetailsJames Ady
EPD breaker installed for roof heat
Kitchen/pantry outlets energized Phone #: ###-#### Inspection requested via web by Heath Thomas Corrections made final ok
Final4/13/20204/14/20204/14/2020AFAIL
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Heath Thomas 426.28 Ground fault protection of equipment shall be provided for Fixed electric snow melting equipment. 210.63 Service recep needed within 25ft of minisplit and on the same level. 110.3 Counter receps to the right of kitchen sink dead. Missing panel cover screws.
Electrical Rough-In11/19/201911/19/201911/19/2019PPASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Heath Thomas rough in ok
Rough-In Permanent Service11/15/201911/18/201911/18/2019ACANC
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Heath Thomas
Electrical Rough-In11/18/201911/18/201911/18/2019PPART
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Heath Thomas Partial only OK to foam seal only. Need misc mud rings installed through out house
Permanent Service11/18/201911/18/201911/18/2019PPASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Heath Thomas Back fill will be brought in to ensure a 6ft 7in max breaker hieght on main. p/s u/g n ok
Electrical Rough-In8/23/20198/26/20198/26/2019APASS
DetailsJames Ady
PVC conduit and floor boxes for 6 in slab floor receptacles. Phone #: ###-#### Inspection requested via web by Heath Thomas Under slab ok to cover