Final | 9/5/2019 | 9/10/2019 | 9/10/2019 | P | FAIL |
Rock A. Hudson
|
|
|
Apartment 201, top left. Compressor is on the north side of the building, right behind the Left Hand garage. The breaker panel is inside the apartment on an interior wall, so we ran 12/2 NM up into the attic and over to a j-box that''s on the end of EMT stubbed in from outside, and #12 wires from there down the outside of the bldg to the local disconnect. Phone #: ###-#### Inspection requested via web by Dan Hilke 300.10-This is for HVAC coated MC termination. MC shall terminate in KO with an approved connector listed for cable used. No answer at door to confirm 20 amp overcurrent device.
|
Final | 9/4/2019 | 9/5/2019 | 9/5/2019 | P | CANC |
Rock A. Hudson
|
|
|
Compressor is on the north side of the building behind the left garage. Panel is in an interior wall so we went into the attic with 12-2 NM to a j-box that''s on EMT stubbed in from outside, and #12 wires down the outside of the building from there to the local disconnect. Please call if you want me to meet you there, I''ll be available after 1pm. Phone #: ###-#### Inspection requested via web by Dan Hilke Called contact to verify access and owners had to leave. Job will be rescheduled.
|