Permit NumberELE19-03424
StatusFinaled
Name TOTAL PRECISION ELECTRIC LLC
Site Address 4701 W JEWELL ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: Remodel
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final11/20/201911/20/201911/20/2019PPASS
DetailsEric Story
Phone #: ###-#### Inspection requested via web by Tyler Ridley
Corrections fixed- Final ok
Final11/18/201911/19/201911/19/2019AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Tyler Ridley
110.3- 3 outdoor receptacle outlets not working. Not hot.
110.22- Furnace disconnecting means shall be identified.
334.30- Kitchen island, NM cable shall not be installed where subject to damage. Flex installed to protect NM cable shall protect entire length.
342.30- IMC service riser shall be secured in place with in 3' of meter/ panel combo.
356.30- Non-metallic flexible conduit below meter/ panel combo shall be secured with in 12" of termination.
Electrical Rough-In10/3/201910/3/201910/3/2019PPASS
DetailsEric Story
Phone #: ###-#### Inspection requested via web by Tyler Ridley
Rough-in ok to cover whole re-wire
Rough-In Permanent Service9/13/20199/16/20199/16/2019APASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Tyler Ridley
Service only.... p/s o/h n ok
Rough-In Permanent Service9/12/20199/13/20199/13/2019AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Tyler Ridley
Idaho power requires 16' minimum over residential driveway. Approx. 13 ' at time of inspection. Increase to 16 and recall.
Rough-In Permanent Service9/11/20199/12/20199/11/2019ACANC
DetailsRock A. Hudson
Phone #: ###-#### >> Inspection requested via web by Tyler Ridley Inspection cancelled from web by: Tyler Ridley