Permit Information
Permit NumberELE19-03503
StatusFinaled
Name DAVID MCCLELLAN CONTRACTING
Site Address 421 S CURTIS RD Unit: 128
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: wire new house completely including 200 amp service and all NEC requirements, hardwired smoke detectors, etc
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/24/20201/24/20201/24/2020PPASS
DetailsTom Saunders
Phone #: ###-#### Inspection requested via web by David McClellan...ok to final
Final1/23/20201/23/20201/23/2020PNR
DetailsTom Saunders
Phone #: ###-#### Inspection requested via web by David McClellan...
post light needs completed...contractor informed
Rough-In Permanent Service11/27/201911/29/201911/29/2019APASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by David McClellan Service inspected by 363 on 10/22/19. p/s u/g n ok
Electrical Rough-In10/22/201910/22/201910/22/2019PPASS
DetailsTom Saunders
adding 2 smokes outside bedrooms Phone #: ###-#### Inspection requested via web by David McClellan...corrections made
rough ok to cover
p/s u/g new ok
Electrical Rough-In10/21/201910/22/201910/22/2019AFAIL
DetailsDaryl DeGrange
fireplace is in. other corrections done Phone #: ###-#### Inspection requested via web by David McClellan Original corrections completed, Building code requires smoke/carbon detectors install outside sleeping areas
Electrical Rough-In10/15/201910/15/201910/15/2019PFAIL
DetailsTom Saunders
Phone #: ###-#### Inspection requested via web by David McClellan...
1) fireplace shall be installed for rough-in inspection
2) manufacturers rating on connector used at panel for branch circuits is rated for no more than 2 NM cables-RC50
3) Foyer wiring - 210.52(I)...3ft wall space needs outlet..2 places