Information based on query as of Thursday, July 4, 2024.
Permit Information
Permit NumberELE19-03735
StatusIssued
Name MACZUGA GERALD J
Site Address 2727 E GLOUCESTER ST
Project Namemaczuga kitchen
Customer Number 
ePlanReviewNo
Description
relocating 3 receptacle outlets and 3 light switches
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Electrical Rough-In1/9/20201/9/20201/9/2020PPASS
DetailsJames Ady
Gerald Phone #: ###-#### Kitchen, Dining and living room ok to cover.
Electrical Rough-In12/23/201912/23/201912/23/2019PNR
DetailsJames Ady
Gerald Phone #: ###-#### Missing power jumpers to Back door switch and U.C light switch. Missing switch legs to U.C light. Missing jumpers between cans R and L of fireplace.Missing jumper to Dish washer recep(Will be under sink not behind Dish washer) Missing Home run to hood location(Will re-use 8-2 to existing cooktop and re-breaker at 20A) All boxes will need made up before rough in.
Conference10/1/201910/2/201910/2/2019ADONE
DetailsRock A. Hudson
GERALD Phone #: ###-####
Unable to talk much due to owner had a conference call shortly after arrival.
Changing wall to living room only and adding an island.
Discussed min receptacle spacing, required to be on small appliance circuit, if micro moves to island dedicated circuit would be needed. Pamphlet given. Owner works as an electrical estimator, seems competent to do work.
Pamphlet given,