Final | 12/2/2019 | 12/3/2019 | 12/3/2019 | A | PASS |
James Ady
|
|
|
Access through side gate to back door Phone #: ###-#### Inspection requested via web by Andy Duckett Countertop in front of panel was removed at time of final. Corrections have been made final ok
|
Final | 11/22/2019 | 11/22/2019 | 11/22/2019 | P | FAIL |
James Ady
|
|
|
back door is open, can go through fence on the side of home Phone #: ###-#### Inspection requested via web by Andy Duckett 314.20 Extension rings needed where boxes set back 1/4in (Devices in tung and groove) 210.8 GFCI protection shal be readily accessible. (Kitchen GFCI behind refer) 110.26A2 Work space shall be 30in measured from edge of panel. (Spoke to cantractor at rough in. Countertop was not going to be installed) Recep for micro needs installed completely and missing plate.
|
Electrical Rough-In | 10/8/2019 | 10/9/2019 | 10/9/2019 | A | PASS |
James Ady
|
|
|
Addition on backside of home. Can access thru gate on the left side Phone #: ###-#### Inspection requested via web by Andy Duckett Addition only ok to cover
|