Final | 11/21/2019 | 11/22/2019 | 11/22/2019 | A | PASS |
Tom Saunders
|
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt...ok to final
|
Rough-In Permanent Service | 10/15/2019 | 10/15/2019 | 10/15/2019 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt Rough in ok cover p/s u/g n ok
|
Rough-In Permanent Service | 10/14/2019 | 10/15/2019 | 10/15/2019 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt 300.4- Wher NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected from damage by nail plates. 334.23- NM cable run on trusses within 7' of attic access shall be protected by guard strips. 334.30- NM cable shall be secured within 8" of island receptacle.
|