Final | 3/24/2020 | 3/25/2020 | 3/25/2020 | A | PASS |
Mark Moncarr
|
|
|
Corrections have been taken care of. Should be good to go. Please call if you have any questions. Thanks Shane Phone #: ###-#### Inspection requested via web by Shane Roe Ok cover. Corrections made.
|
Final | 3/16/2020 | 3/17/2020 | 3/17/2020 | P | FAIL |
Mark Moncarr
|
|
|
The front door might be locked. If so try the back door. Phone #: ###-#### Inspection requested via web by Shane Roe 1. Lighting in bedroom and back porch need ARC fault protection. 2. Smoke detectors need ARC fault protection. Can put on bed circuit. 3. AC neutral needs identified as hot conductor. 4. Service recept needed as well for AC. 5. Recept on W side of island needs blanked. Under more than a 6" overhang.
|
Conference | 12/27/2019 | 12/30/2019 | 12/30/2019 | A | DONE |
Mark Moncarr
|
|
|
Need to discuss Eric''s finding regarding 225.32. Conduit feeding panel in the house is buried greater than 18" below grade. Hoping to discuss a practical solution. Phone #: ###-#### Inspection requested via web by Shane Roe Discussed not having to provide a disconnect on exterior as conduit is 18" in ground below the structure.
|
Electrical Rough-In | 12/27/2019 | 12/27/2019 | 12/27/2019 | A | FAIL |
Eric Story
|
|
|
awaiting new fan for existing bathroom, should not affect remaining areas. Phone #: ###-#### Inspection requested via web by Shane Roe 225.32 Location of Disc shall be installed when enetering a structure 300 bored holes when hole is 1 1/4 from face of wood member shall have a listed nail plate to protect wires Ok to insulate attic and walls at this time(just nned to check nail plates)
|
Permanent Service | 11/19/2019 | 11/19/2019 | 11/19/2019 | P | PASS |
Mark Moncarr
|
|
|
New electrical service, mounted on the back side of the garage toward the alley. Phone #: ###-#### Inspection requested via web by Shane Roe Notified contractor that IDP may not except mast diameter unless IDP designer approved it. 1-1/2" was used p/s o/h n ok
|
Electrical Rough-In | 10/17/2019 | 10/17/2019 | 10/17/2019 | P | PASS |
Mark Moncarr
|
|
|
Underground conduit Phone #: ###-#### Inspection requested via web by Shane Roe Ok cover conduit from house to alley side of garage.
|