Permit Information
Permit NumberELE19-04006
StatusFinaled
Name SILVER ELECTRIC LLC
Site Address 2726 N 29TH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: Installing a new 125A 240/120volt service on outbuilding. Rough-in new 800 sqft addition to existing house. There will be a new 125A panel installed in the new addition that will power the existing circuits in the house. A temporary feed will be instal
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/24/20203/25/20203/25/2020APASS
DetailsMark Moncarr
Corrections have been taken care of. Should be good to go. Please call if you have any questions.
Thanks
Shane Phone #: ###-#### Inspection requested via web by Shane Roe Ok cover. Corrections made.
Final3/16/20203/17/20203/17/2020PFAIL
DetailsMark Moncarr
The front door might be locked. If so try the back door. Phone #: ###-#### Inspection requested via web by Shane Roe
1. Lighting in bedroom and back porch need ARC fault protection.
2. Smoke detectors need ARC fault protection. Can put on bed circuit.
3. AC neutral needs identified as hot conductor.
4. Service recept needed as well for AC.
5. Recept on W side of island needs blanked. Under more than a 6" overhang.
Conference12/27/201912/30/201912/30/2019ADONE
DetailsMark Moncarr
Need to discuss Eric''s finding regarding 225.32. Conduit feeding panel in the house is buried greater than 18" below grade. Hoping to discuss a practical solution. Phone #: ###-#### Inspection requested via web by Shane Roe Discussed not having to provide a disconnect on exterior as conduit is 18" in ground below the structure.
Electrical Rough-In12/27/201912/27/201912/27/2019AFAIL
DetailsEric Story
awaiting new fan for existing bathroom, should not affect remaining areas. Phone #: ###-#### Inspection requested via web by Shane Roe
225.32 Location of Disc shall be installed when enetering a structure
300 bored holes when hole is 1 1/4 from face of wood member shall have a listed nail plate to protect wires
Ok to insulate attic and walls at this time(just nned to check nail plates)
Permanent Service11/19/201911/19/201911/19/2019PPASS
DetailsMark Moncarr
New electrical service, mounted on the back side of the garage toward the alley. Phone #: ###-#### Inspection requested via web by Shane Roe Notified contractor that IDP may not except mast diameter unless IDP designer approved it. 1-1/2" was used p/s o/h n ok
Electrical Rough-In10/17/201910/17/201910/17/2019PPASS
DetailsMark Moncarr
Underground conduit Phone #: ###-#### Inspection requested via web by Shane Roe Ok cover conduit from house to alley side of garage.