Final | 4/7/2020 | 4/8/2020 | 4/8/2020 | A | PASS |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Corrections fixed final ok Occ card signed
|
Final | 4/6/2020 | 4/7/2020 | 4/7/2020 | A | FAIL |
Eric Story
|
|
|
Call Efren 1/2 hr prior so he can meet you there Phone #: ###-#### Inspection requested via web by Lee VanSchoiack 210.8 Recetpacles located within 6' of a sink shall have GFCI protection 406 All receptacles located in outdoors shall be WR rated 300 Spark ring required behind combustible material(entry in wood wall) OCPD exceeds water heater rating at 23 amps 30 installed
|
Permanent Service | 2/10/2020 | 2/10/2020 | 2/10/2020 | P | PASS |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack AFC calc posted 7,472- breakers are rated at 22K U/G not installed at time of inspection p/s u/g n ok
|
Rough-In Permanent Service | 2/5/2020 | 2/6/2020 | 2/6/2020 | A | CANC |
Eric Story
|
|
|
around 11am if possible Phone #: ###-#### Inspection requested via web by Lee VanSchoiack
|
Permanent Service | 2/6/2020 | 2/6/2020 | 2/6/2020 | P | FAIL |
Eric Story
|
|
|
around 11am if possible Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Rating posted on prints states 34,000 and breakers are rated at 22K, replace with larger sized frame of breaker
|
Electrical Rough-In | 2/6/2020 | 2/6/2020 | 2/6/2020 | P | PASS |
Eric Story
|
|
|
around 11am if possible Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Rough-in ok to cover
|
Electrical Rough-In | 2/3/2020 | 2/3/2020 | 2/3/2020 | P | PASS |
Eric Story
|
|
|
exterior soffit cans Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Approved plans on site Entry soffit cans ok to cover
|
Electrical Rough-In | 12/24/2019 | 12/24/2019 | 12/24/2019 | A | PASS |
Eric Story
|
|
|
ufer Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Uffer ok to cover
|