Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberELE20-00202
StatusFinaled
Name POWER PRO ELECTRICAL CONTRACTORS
Site Address 2918 E EASTGATE DR
Project Name 
Customer NumberMagalsky
ePlanReviewNo
Description
Addition: Upgrade existing 100A service to a 200A service, all appliances will be gas. Extend existing kitchen circuits to expanded wall and relocated Island. Rough in new addition including 2 future bedrooms, 1 bathroom, small family room, and kitchen area.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/10/20203/11/20203/11/2020APASS
DetailsJames Ady
The homeowner will be home in the morning and has reported that HVAC did come out and replace the fittings for the mini split with the proper fittings. Please let me know if you have any questions. Thank you! Phone #: ###-#### Inspection requested via web by Dan Jennings Corrections made final ok
Final3/8/20203/9/20203/9/2020AFAIL
DetailsJames Ady
The homeowner has stated that he will be home Monday morning. Please let me know if you have any questions. Thank you! Phone #: ###-#### Inspection requested via web by Dan Jennings 110.3B Jacketed MC shall terminate in a listed connector. (Mini split)
Final3/4/20203/6/20203/6/2020ANH
DetailsJames Ady
The homeowner will be home Friday morning. The addition has a future second kitchen in it but the cabinets won''t be installed for years potentially. Everything is trimmed out except the microwave outlet because there isn''t a cabinet yet. Instead we installed a 4sq box with blank cover. The box is grounded and the wires saved off. Please let me know if you have any questions. Thank you! Phone #: ###-#### Inspection requested via web by Dan Jennings no answer at door no access
Final3/4/20203/6/20203/4/2020ACANC
DetailsJames Ady
The homeowner will be home Friday morning. The addition includes a future second kitchen but the cabinets won''t be installed for years potentially. Everything is trimmed out except the microwave outlet which has a 4sq outlet with blank cover on it. Please let me know if you have any questions. Phone #: ###-#### >> Inspection requested via web by Dan Jennings Inspection cancelled from web by: Dan Jennings
Electrical Rough-In2/4/20202/5/20202/5/2020APASS
DetailsJames Ady
Good afternoon, we have addresses the shoddy staple work. Flat cables are now stalled flat, stackers have been installed at busy locations, and general quality of sta pl ling has been corrected. Thank you, Dan Phone #: ###-#### Inspection requested via web by Dan Jennings Corrections made Master bed, Laundry room, Living room and Kitchen ok to cover.
Electrical Rough-In2/3/20202/4/20202/4/2020AFAIL
DetailsJames Ady
Good evening, the homeowner will not be home but the side gate and side door to the addition will be open. This is for the rough in for the addition, the rough in for the kitchen remodel was already completed as well as the service upgrade. Please let me know if you have any questions! Thank you, Dan Phone #: ###-#### Inspection requested via web by Dan Jennings 334.30 Flat NM cables shall not be securred on edge. 300.4D Cables shall not be secured less than 1 1/4in from face of framing. (Master bath 3 gang, Side entry 2 gang, Back slider 2 gang, Fan/ Fan light 2 gang)
Permanent Service1/30/20201/30/20201/30/2020PPASS
DetailsJames Ady
Service is being upgraded to 200A from 100A. Requesting inspection so the customer can get their service re-energized. Thank you! Phone #: ###-#### Inspection requested via web by Dan Jennings p/s u/g rec ok
Electrical Rough-In1/17/20201/21/20201/21/2020PPASS
DetailsJames Ady
This inspection request is just for the kitchen remodel portion of this work. The service upgrade and rough in for the addition have not been started yet. The kitchen is expanding about 3-4 feet north and getting new cabinets. Please give me a call if there are any questions.Also, the homeowner said they would be available in the afternoons by 2pm....possibly by 1pm. Thank you! Phone #: ###-#### Inspection requested via web by Dan Jennings kitchen only ok to cover