Final | 7/22/2020 | 7/23/2020 | 7/23/2020 | P | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wake Down bed GFCI is controlled by wall switch and protects outdoor recep. Air screens contorlled by wall switch Corrections made final ok
|
Final | 7/21/2020 | 7/22/2020 | 7/22/2020 | A | FAIL |
Rock A. Hudson
|
|
|
Garage code 4908 Phone #: ###-#### Inspection requested via web by Ryan Wake 110.3- Equipment shall work as per instructions. Island counter top receptacles and down bed GFCI behind dor not working. 210.52(C)- Pantry counter top spaces shall have receptacle outlets installed so that not point on counter top is more than 24" from a receptacle outlet. 314.23- Island pop-up receptacle assemblies shall be secured in place. * unable to verify a disconnecting means for air curtain.
|
Electrical Rough-In | 6/10/2020 | 6/11/2020 | 6/11/2020 | A | PASS |
James Ady
|
|
|
garage code 4908. Master bath floor heat rough in Phone #: ###-#### Inspection requested via web by Ryan Wake Master floor heat only ok to cover
|
Rough-In Permanent Service | 2/26/2020 | 2/27/2020 | 2/27/2020 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wake Corrections made rough in ok p/s u/g n ok
|
Rough-In Permanent Service | 2/25/2020 | 2/26/2020 | 2/26/2020 | A | FAIL |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wake 300.4A1 Bored holes less than1 1/4in from face of stud shall have nail plates(Master Bed right of sliding door emerging from crawl) 110.14A Acorn shall ensure a thoroughly good connection. (UFER)
|
Electrical Rough-In | 1/30/2020 | 1/31/2020 | 1/31/2020 | A | PASS |
James Ady
|
|
|
soffit cover inspection Phone #: ###-#### Inspection requested via web by Ryan Wake Soffits only ok to cover
|