Final | 2/12/2020 | 2/12/2020 | 2/12/2020 | P | PASS |
Mark Moncarr
|
|
|
Ok final. GFI functions properly, refer is tamper resistant
|
Electrical Rough-In | 2/11/2020 | 2/12/2020 | 2/12/2020 | A | PASS |
Mark Moncarr
|
|
|
Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg Ok cover wall behind and to side of new refer location.
|
Electrical Rough-In | 2/11/2020 | 2/11/2020 | 2/11/2020 | P | FAIL |
Mark Moncarr
|
|
|
1. Recept was added to kitchen countertop off circuit somewhere in the house because it is new 14ga wire. Needs to be on 20a circuit. 2.Upon final, tamper resistant recept needs installed for refer. I will need access behind refer to verify.
|
Final | 2/10/2020 | 2/11/2020 | 2/11/2020 | P | CANC |
Mark Moncarr
|
|
|
Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg 1. 14ga wire comes from another circuit in the house to power a kitchen countertop recept. Wire needs to be 12ga. 2. Upon final, recept needs to be tamper resistant for refer.
|