Final | 6/10/2020 | 6/10/2020 | 6/10/2020 | P | PASS |
Tom Saunders
|
|
|
All Corrections Done Phone #: ###-#### Inspection requested via web by jason shifflett... corrections made...ok to final
|
Final | 6/9/2020 | 6/9/2020 | 6/9/2020 | A | FAIL |
Tom Saunders
|
|
|
This Is All Done And Ready For Final Sir Thanks So Much Ill Make sure Is Open For You This Morning Phone #: ###-#### Inspection requested via web by jason shifflett...
1) oulets shall be complete at time of final...missing plate at receptacle in pantry 2) receptacles within 6ft of water shall have GFCI protection...mst closet/mst bath tub 3) recesed lighting shall be 6" away from edge of shelf in closet...mst closet 4) incandescent surface mounted lighting shall be 12" away from edge of shelf in closet...hall closet
|
Permanent Service | 2/21/2020 | 2/21/2020 | 2/21/2020 | P | PASS |
James Ady
|
|
|
We Should Be Already By 100 Thanks So Much! Dave Phone #: ###-#### Inspection requested via web by jason shifflett p/s u/g n ok
|
Electrical Rough-In | 2/21/2020 | 2/21/2020 | 2/21/2020 | P | PASS |
James Ady
|
|
|
We Should Be Already By 100 Thanks So Much! Dave Phone #: ###-#### Inspection requested via web by jason shifflett rough in ok
|