Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberELE20-00894
StatusFinaled
Name TEN FORTY ELECTRIC
Site Address 2823 W REGAN AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: New 200a service
Partial interior remodel
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/16/20206/17/20206/17/2020APASS
DetailsRock A. Hudson
I’ll meet you there to walk through inspection, thank you Phone #: ###-#### Inspection requested via web by Keith Chetta Final ok
Final6/11/20206/12/20206/12/2020ANR
DetailsRock A. Hudson
Reinspection for required gfci’s and tamper proofs Phone #: ###-#### Inspection requested via web by Keith Chetta
Was met at door by an individual who said he is working on corrections but this individual is not licenced and does not work for the electrical contractor. Will call prior to next inspection to confirm who scheduled and who complete work. Next time someone caught doing work without proper documentation will be turned into state for possible fines and reinspection fees.
Final6/10/20206/11/20206/11/2020AFAIL
DetailsRock A. Hudson
Call me when you are there and I’ll give you the lock box code if no one is home, thank you. Kitchen remodel Phone #: ###-#### Inspection requested via web by Keith Chetta
210.8(A)- All receptacle outlets serving counter top areas shall have GFCI protection. Left of refer and right of sink.
406.12- All receptacle outlets in kittchen remodel area shall be tamper resistant type. Left of refer.
Electrical Rough-In4/13/20204/14/20204/14/2020APASS
DetailsMark Moncarr
Another tradesman will be working on site, building is accessible. The residence has been unoccupied for atleast a week. Jobsite is open, clean and open air. I will not be there, please call me if you have any questions, thank you Phone #: ###-#### Inspection requested via web by Keith Chetta Ok cover kitchen, bath and utility
Permanent Service4/1/20204/2/20204/2/2020PPASS
DetailsMark Moncarr
Upgrading a 100a service to a 200a service, I will be on site Phone #: ###-#### Inspection requested via web by Keith Chetta p/s o/h rec ok
Conference3/13/20203/16/20203/16/2020ADONE
DetailsMark Moncarr
I will be at another job site in Boise , please give me a 30 min eta and I will meet you there, thank you Phone #: ###-#### Inspection requested via web by Keith Chetta Conference was service drop over property. Told contractor this would be an IDP issue. Low hanging drop is from a IDP supplied pole at rear of property that is leaning towards the home causing service drop to lay on roof of property next door.