Permit Information
Permit NumberELE20-01470
StatusIssued
Name COWAN ELECTRIC LLC
Site Address 37 S MESA VISTA DR
Project Name 
Customer Number20-10
ePlanReviewNo
Description
Alteration or Repair: Replace service and all branch circuits to update the homes electrical and remove the two wire system.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Electrical Rough-In6/27/20206/29/20206/29/2020APASS
DetailsEric Story
3366 is code for the contractor box right of the main door. Phone #: ###-#### Inspection requested via web by Jack Cowan

Corrections fixed-Rough-in ok to cover
Electrical Rough-In6/20/20206/22/20206/22/2020AFAIL
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Jack Cowan 300.4D Cables shall not be secured within 1 1/4in from face of stud. (Areas through out) 300.4A1 Cables ran through bored hole within 1 1/4in from face of the stud shall have nail plates. (Areas through out) 334.30 Flat cbles shall not be stapled on edge. (Areas through out) 210.52E3 Recep needed on back patio. 210.52 A2 2 receps needed along Living room window wall where concrete has been removed. 300.5B Interior of a conduit ran underground shall be considered a wet location 334.12B4 NM cable shall not be installed in a wet location. Smoke detectors shall be installed.
Rough-In Permanent Service5/26/20205/26/20205/26/2020PPASS
DetailsEric Story
Side gate is open on the east. Service is in the back. This is a 200A Meter Main outside with one outlet. Then a 200A subpanel in the basement. Sliding glass door in the back of the house
should be open. Only want to energize the service for power. Will request a rough-in later. Phone #: ###-#### Inspection requested via web by Jack Cowan
p/s o/h n ok