Final | 6/9/2020 | 6/9/2020 | 6/9/2020 | A | PASS |
Mark Moncarr
|
|
|
Code 8008 Phone #: ###-#### Inspection requested via web by Nick Larson Ok final pool. 40a GFI brkr from inside garage panel runs exterior 6/12 panel.
|
Electrical Rough-In | 6/5/2020 | 6/5/2020 | 6/5/2020 | P | PASS |
Mark Moncarr
|
|
|
Equapotential plane inspection for new pool Phone #: ###-#### Inspection requested via web by Nick Larson Ok cover EQ plane. 4"-6" deep as per code.
|
Electrical Rough-In | 5/7/2020 | 5/8/2020 | 5/8/2020 | A | PASS |
Mark Moncarr
|
|
|
underground inspection for underground conduit Phone #: ###-#### Inspection requested via web by Nick Larson Ok cover grd work to pool equipt.
|
Electrical Rough-In | 5/2/2020 | 5/4/2020 | 5/4/2020 | A | PASS |
Mark Moncarr
|
|
|
bonding inspection Phone #: ###-#### Inspection requested via web by Nick Larson Ok cover. 4 corners bonded. Perimeter will not be concrete surface. EQ plane, when done, will need to be between 4"-6" deep for inspection.
|