Permit Information
Permit NumberELE97-03295
StatusFinaled
Name QUALITY ELECTRIC INC
Site Address 5792 S HORSESHOE PL
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP - Final11/26/199711/28/199711/28/1997APASS
DetailsJack Frank
11/28/97 315 - 1ST THING FRI AM PLEASE 14 ok jf
INSP - Final11/24/199711/25/199711/25/1997AFAIL
DetailsJack Frank
11/25/97 315 - REINSPECTION 14 failed jf cor. posted NEC, 410-8 2 bedroom closets, 370-20 micro wave outlet, 210-52(b) d w & disposal not allowed on kit. circuits, 336-6 pro romex at furnace terminate unused romex in basement in j boxes
INSP - Final11/21/199711/24/199711/24/1997APASS
DetailsMarv Burrus
LARRY WILL CALL TO SCHEDULE WITH YOU NEC: 210-8. GFCI IN KITCHEN REQUIRED. BOISE CITY ENERGY CODE: IN HOUSE FAN REQUIRES TIMER AND MANUAL SWITCH. (MANUAL SWITCH NOT OPERATING FAN.) BCC. RECEPTICLE IN ENTRY HAS NUETRAL NOT CONNECTED CORRECTLY.
INSP - Ele Rough-In/Perm Svc9/30/19979/30/19979/30/1997PPASS
DetailsMarv Burrus
PLEASE CALL LARRY AT ###-#### VOICE PAGER BEFORE YOU GO OUT THERE
INSP - Ele Rough-In/Perm Svc9/29/19979/29/19979/29/1997PNR
DetailsMarv Burrus
09/29/97 403 - BASEMENT INSTALLATION NOT COMPLETED. WILL RESCHEDULE.