INSP - Final | 3/8/1999 | 3/9/1999 | 3/9/1999 | A | CANC |
Marv Burrus
|
|
|
SHELLY ###-#### PREVIOUSLY INSPECTED ON 03-05-99, PASSED AT THAT TIME.
|
INSP - Final | 3/5/1999 | 3/5/1999 | 3/5/1999 | P | PASS |
Marv Burrus
|
|
|
03/05/99 403 - reinspect final ###-#### CORRECTIONS COMPLETED. OK
|
INSP - Final | 3/3/1999 | 3/4/1999 | 3/4/1999 | P | FAIL |
Marv Burrus
|
|
|
Scheduled by Hello!. Contact phone is [8704261]. UNIT# 3930: NEC: 210-52(B).2 SMALL APPLIANCE BRANCH CIRCUITS IN KITCHEN REQUIRED.NEC 210-52(A).RECEPTICLE OUTLET REQUIRED IN EVERY 2 FEET OF LINEAR WALL. UNIT# 3932: NEC: 210-8(A)(3): SHALL HAVE GFCI RECEP. OUTSIDE. NEC: 210-52(A): RECEP. OUTLET REQUIRED IN 2 FT. OF WALL.
|
INSP - Final | 2/10/1999 | 2/11/1999 | 2/11/1999 | P | FAIL |
Marv Burrus
|
|
|
02/10/99 403 - Scheduled by Hello!. Contact phone is [8594417]. NOT READY FOR INSPECTION.
|
INSP - Electrical Rough-In | 2/10/1999 | 2/10/1999 | 2/10/1999 | P | PASS |
Marv Burrus
|
|
|
PERM/SVC ONLY. OK
|
INSP - Final | 2/9/1999 | 2/10/1999 | 2/10/1999 | P | CANC |
Marv Burrus
|
|
|
02/10/99 403 - Scheduled by Hello!. Contact phone is [8594417]. REQUEST WAS FOR PERM/SVC R/I.
|
INSP - Electrical Rough-In | 9/23/1998 | 9/23/1998 | 9/23/1998 | P | PASS |
Marv Burrus
|
|
|
09/23/98 403 - debbie ###-#### TOWNHOUSE; ELE R/I AND PERM/SVC. OK
|