Final | 4/16/2002 | 4/17/2002 | 4/17/2002 | A | PASS |
Marv Burrus
|
|
|
monica ###-#### call for access. corrections completed, 4/17/2002 8:40:10 AM
|
Final | 4/2/2002 | 4/3/2002 | 4/3/2002 | A | FAIL |
Marv Burrus
|
|
|
###-#### monica call for access. not all corrections completed. 4/3/2002 11:02:03 AM
|
Final | 10/11/2001 | 10/12/2001 | 10/12/2001 | A | FAIL |
Marv Burrus
|
|
|
monica ###-#### fn--call 1st before insp. nec: 210-8. bathrooms shall have gfci protection for recepticle outlets. nec: 210-52. kitchen island cupboards shall have at least one gfci receptile outlet. 410-8. closet incandescant light fixture shall be at least 12 inches clearance or width of shelf which ever is greater, 10/12/2001 11:46:48 AM
|
Electrical Rough-In | 8/9/2000 | 8/10/2000 | 8/10/2000 | P | PART |
Marv Burrus
|
|
|
Luke ###-####. remodel, ele r/i only. 8/10/2000 7:53:18 PM
|