Information based on query as of Friday, July 11, 2025.
Permit Information
Permit NumberESC08-00575
StatusExpired
Name SUMMER KLAHR
Site Address 3900 E AMITY RD
Project NameSOLAIRE SUB
Customer Number 
ePlanReview 
Description
Permit is for site development only, does not include structures.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Expired7/9/20097/9/20097/9/2009PPASS
DetailsClint A Smith
General Inspection ESC7/6/20097/6/20097/6/2009 DONE
DetailsClint A Smith
No activity
Site Final6/3/20096/3/20096/3/2009APART
DetailsSteven Webb
Reviewed status of project with Hopkins Financial regarding requirement of ESC. Site has fairly consistent top growth of coverage but BMPs and dirt in gutter pan exists at misc. areas. Not ready to final.
General Inspection ESC5/29/20095/29/20095/29/2009 FAIL
DetailsClint A Smith
Stop work order still inplace. Have not been sucessful with contacting the RP and or the RP contactting the city. No activity.
INSP - Stop Work Order4/28/20094/28/20094/28/2009PFAIL
DetailsClint A Smith
Must submit an up to date contact information of the RP to the City of Boise prior to the start of work. Also Must contact Steve Webb and/or Clint Smith to correct all violations pertaining with 8-17.
General Inspection ESC4/27/20094/27/20094/28/2009 FAIL
DetailsClint A Smith
STOP WORK ORDER:
Must provide the proper contact information to the City of Boise. Once contacted must correct all viotations pertaining to 8-17.
General Inspection ESC3/26/20093/26/20093/26/2009 PART
DetailsClint A Smith
Message to RP:
Advised RP over stabilizing stock pile at the back portion of the project area. In inactive for reasons of dust control
General Inspection ESC2/23/20092/23/20092/23/2009 PASS
DetailsClint A Smith
No activity.
Tracking Control1/15/20091/21/20091/21/2009APART
DetailsClint A Smith
Left message with RP:
Make sure that subs clean up at the end of the day off any issues. (tracking or trash debris ect..)
General Inspection ESC1/15/20091/15/20091/15/2009 FAIL
DetailsClint A Smith
Left a message for the RP at the number given.
Clean up all sediment and debris off of all hard surfaces trough out the whole subdivision. Will re-inpsect on 1/21/09
BMP Violation12/9/200812/15/200812/15/2008AFAIL
DetailsClint A Smith
Need to install some structural BMP once able to install. Due to freeze will give them till the first frost melt.
BMP Violation12/8/200812/9/200812/9/2008AFAIL
DetailsClint A Smith
Moved till 12/15/08.
Conference12/8/200812/9/200812/9/2008ADONE
DetailsClint A Smith
see prior inspection.
Conference12/8/200812/9/200812/9/2008ADONE
DetailsSteven Webb
See #420 Steve Webbs inspection notes.
BMP Violation12/5/200812/5/200812/5/2008AFAIL
DetailsClint A Smith
(left a message with the RP at the office)
Correction Notice:
1. Install sediment protection on all areas of project that are over 2% grade or if the grave elevation is higher than the sidewalk or where is can impead on the MS4 system.
2. Clean all hard surface of alll sediment and debris.
BMP Violation11/6/200811/10/200811/10/2008PPART
DetailsClint A Smith
General Inspection11/6/200811/6/200811/6/2008AFAIL
DetailsClint A Smith
Spoke with the IRP
Verbal correction:
1. Correct the payment with your IRP within the city.
2. Protect all storm drain inlets on project area.
3. Clean up tracking at east side access and block off or construct an approved construction access.
4. Clean up all sediment off of sidewalks and install perimeter controls where grade is over 2% slope to the sidewalks or cut a releaf trench right behind the sidewalk.
5.Install a sediment barrier protection at end of the street at the bikepath.
General Inspection ESC10/28/200810/28/200810/28/2008 PASS
DetailsJames Rogers
Tracking Control9/23/20089/25/20089/25/2008APASS
DetailsClint A Smith
BMP Violation9/22/20089/23/20089/23/2008AFAIL
DetailsClint A Smith
Notice of Correction. Left a message for the RP.
Install a stabilized construction entrance at the front of the project.
Install access control to deliniate the construction entrance.
Failure to comply will result in further enforcement.
Wil re-inspect on 9/25/08.
Due to the phase of construction they will be given to the time of 9/2508.
BMP Violation9/22/20089/22/20089/22/2008PDEFR
DetailsClint A Smith
Moved to 8/23/08 due to the progress as of today.
General Inspection9/19/20089/22/20089/22/2008ADEFR
DetailsClint A Smith
Moved to this afternoon. Spoke with the RP and will be completed by the end of the work day.
Tracking Control8/15/20088/20/20088/20/2008APASS
DetailsClint A Smith
Tracking Control8/14/20088/15/20088/15/2008APART
DetailsClint A Smith
Entrance re-constructed but access control will be needed to keep vechile from entrering and exiting other areas of the project. Left a message with the RP to contact me. Will re-inspect on 8/20/08.
CAS
Tracking Control8/13/20088/14/20088/14/2008PPART
DetailsClint A Smith
Have made a temporary entrance in the center of the project. No tracking has occured at this time. Will re-inspect on 8/15/08
CAS
Tracking Control8/13/20088/13/20088/13/2008APASS
DetailsClint A Smith
Cleaned up tracking from the day prior. Will be closing off the entrance to the site and will be using an alternate access point for a short period of time. THen they will go back to the entrance and will be stabilized. Street sweeping will be used in the period of time if any tracking occurs through the duration of using the alternate access point.
Will re-inspect on 8/14/08
CAS
General Inspection7/30/20087/30/20087/30/2008PPART
DetailsSteven Webb
Overall site looks ok; appears vehicle traffic has bypassed rock construction entrance at times and driven on bare dirt; rock entrance could be increased in width to address this problem.
Conference7/18/20087/18/20087/18/2008APASS
DetailsClint A Smith
General Inspection7/7/20087/9/20087/9/2008APASS
DetailsSteven Webb
Site Preparation7/3/20087/7/20087/7/2008APART
DetailsSteven Webb
Partial compliance to approved plan. Sign at construction entrance did not have permit number included on the sign. Ok to work but RP must have day-to-day control. Will follow up.