Aging Inspection | 5/18/2015 | 5/18/2015 | 5/18/2015 | | PASS |
Andy J. Long
|
|
|
All work complete and approved. 4-plexes are occupied and carports have been complete. No construction materials or loose sediment remaining onsite. ESC permit conditions satisfied.
|
DOC - Permit Finaled | 5/18/2015 | 5/18/2015 | 5/18/2015 | P | PASS |
Andy J. Long
|
|
|
|
Aging Inspection | 3/18/2015 | 3/18/2015 | 3/18/2015 | | PART |
Evan Jenkins
|
|
|
Talked with Ken Skaggs. Temp BMP's need to be removed and some sediment needs to be removed prior to closing the ESC permit. People are currenlty moving into the apartments
|
General Inspection | 1/16/2015 | 1/16/2015 | 1/16/2015 | P | PART |
Andy J. Long
|
|
|
Full site permit/grading and drainage for village chaton. 4-plexes covered seperately ESC14-00###-####0
All 4 Village Chaton 4-plexes have been framed. Parking lot and utilities are installed. Interior work is ongoing.
Trash is contained, onsite stormdrain have inlet protection. MS4 DI on Ustick also has filter bag installed. No significant trackout, but site is not yet landscape some sediment is being eroded away.
Need to install wattle along disturbed area next to the sidewalk on Ustick (west side of access road)
|
General Inspection | 12/1/2014 | 12/1/2014 | 12/1/2014 | A | PART |
Andy J. Long
|
|
|
Village Chaton Sub parking lot and sidewalk/curbing is installed. Sheet flow for entire impervious surfaces on site is directed to a central drop inlet with interceptor & frech drain. The inlet has filter bag protection and remaining capacity.
No trackout or offsite discharges to Ustick occuring. Trash is mostly contained in large dumpster with minimal windblown litter. A lined concrete washout was used but is now full and dried so need to be cleaned/removed. All permits posted with SWPPP info.
1 correction: Conduct a general cleanup at site: -pick up waste insulation bundles/fragments -sweep sidewalks and areas of parking lot with loose sediment/dirt -remove concrete washout.
Sub-contractors onsite conducting interior work on 4-plexes currently.
Verbal correction request issued to Andersen Construction RP.
|
Random Inspection | 10/27/2014 | 10/27/2014 | 10/27/2014 | A | PASS |
Andy J. Long
|
|
|
Village Chaton Sub is in progress. Parking lot has been paved and the frames are up for the fourplexes. Permit is posted on job trailer. No trackout to Ustick or sediment leaving jobsite. Approved.
|
Random Inspection | 9/9/2014 | 9/9/2014 | 9/9/2014 | P | PASS |
Andy J. Long
|
|
|
Work has resumed on Village Chaton. Access road and utilities have been installed, now working on the 4 fourplexes (covered under ESC14-00257 to -00260.
No violations observed; permit posted. No complaints received.
|
General Inspection | 8/27/2014 | 8/27/2014 | 8/27/2014 | | PART |
Evan Jenkins
|
|
|
Mass Grading and Foundation Pouring/Prep is occuring prior to site prep inspection approval. Concrete Washout of is completely full, overflowing onto the ground. Permits need to be posted on each individual lot. Dave Skaggs has not returned both phone call attemps.
|
Random Inspection | 6/23/2014 | 6/23/2014 | 6/23/2014 | P | PASS |
Andy J. Long
|
|
|
The driveway/parking lot for Village Chaton is now paved and complete. Permits for the 4 plexes are currently under review. No activity or violations observed at time of inspection.
|
Random Inspection | 5/20/2014 | 5/20/2014 | 5/20/2014 | A | PASS |
Andy J. Long
|
|
|
Drove by Village Chanton enroute to other inspections...
No activity. Entrance has been curbed but not yet paved. No trackout. Permits posted.
|
Random Inspection | 5/13/2014 | 5/13/2014 | 5/13/2014 | P | PASS |
Andy J. Long
|
|
|
Village Chaton. No significant trackout or discharges observed. Permit clearly posted. No dust issues evident at time of inspection @ 3 PM.
No corrections at this time.
|
Random Inspection | 4/24/2014 | 4/24/2014 | 4/24/2014 | P | PASS |
Andy J. Long
|
|
|
The water and utilities have now been installed, so the construction entrance can be replenished for use. No work at time of inspection. No trackout or violations. Vegetative buffer along sidewalk.
|
Site Preparation | 4/8/2014 | 4/9/2014 | 4/9/2014 | A | PASS |
Andy J. Long
|
|
|
site prep - Village Chaton grading and sub development permit. Phone request by Jim with Andrersen Construction ###-####. 9 AM
Attended project pre-con meeting and was able to discuss the SWPPP with Andersen Construction and Knife River.
BMPs include: 1. DI protect 2. 60'x18' rock construction entrance (no fabric for this temporary phase. 3. Perimeter wattles 4. Undisturbed vegetative strip along sidewalk
Permit posted, SWPPP onsite. I will retain construction schedule. Approved.
|
Site Preparation | 4/8/2014 | 4/8/2014 | 4/8/2014 | A | CANC |
Andy J. Long
|
|
|
scheduled for 9 AM Wednesday April 9
|