Information based on query as of Tuesday, June 25, 2024.
Permit Information
Permit NumberESC14-00393
StatusFinaled
Name CHAD CROCKER
Site Address 2235 N PLEASANT HILL WAY
Project NameSomerset Ridge 4-blk 4,lot 47
Customer Number 
ePlanReviewNo
Description
AS Per ESC conditions, Site has been preliminary grated and has roof drain stormwater stub/inlet already existing. Building pad is flat but is surrounded by slopes. Drop inlet protection and fiber rolls (wattles) must be installed per ESC plan prior to excavation. Trackout control may require a stabilized construction entrance, but if dry may not be necessary and any trackout should be swept daily; dust control must be implemented as necessary; and proper waste management for concrete washout and construction waste.ESC site preparation inspection required.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection4/15/20154/15/20154/15/2015 PASS
DetailsAndy J. Long
DI bag removed on inlet from Pleasant Hill. Onsite ESC issues addressed. Permit conditions satisfied. Home occupied and stabilized.
DOC - Permit Finaled4/15/20154/15/20154/15/2015PPASS
DetailsAndy J. Long
General Inspection3/31/20153/31/20153/31/2015 PASS
DetailsAndy J. Long
Rill erosion on perimeter banks from lawn irrigation has been raked out/graded and hydoseeded in addition to the shoulders of the driveway.

Just need to remove DI bag on Pleasant Hill and site will be ready to final.
General Inspection3/16/20153/16/20153/16/2015 PEND
DetailsAndy J. Long
Trackout and sediment accumulation on Pleasant Hill has been cleaned. Driveway is now paved and the driveway shoulders have been hydroseeded. Project is near completion.

Irrigation of recently installed sod has created some rill erosion on interior banks that will need to be fixed to pass site final and DI bag on Pleasant Hill removed.
General Inspection2/27/20152/27/20152/27/2015 FAIL
DetailsAndy J. Long
Significant amount of sediment and sand has accumulated on street and gutter from unpaved driveway with no stabilized construction entrance

Corrections:

Sweep up street, sidewalk and gutter that is downhill from site. Should be cleaned over the weekend.

2nd failed inspection/warning
General Inspection2/12/20152/12/20152/12/2015 FAIL
DetailsEvan Jenkins
Excessive trackout from site, going down Clubview. Contacted RP Chad and left VM disclosing the violation. told him to sweep up excessive trackout, and limit the amount of vehicle traffic entering and exiting Pleasant Hill Way
Random Inspection2/12/20152/12/20152/12/2015PCANC
DetailsEvan Jenkins
Excessive Trackout
Data Entry Error: Didn't realize already have a general inspection for this site
General Inspection1/28/20151/28/20151/28/2015 PASS
DetailsAndy J. Long
WIP. No corrections needed.
General Inspection1/13/20151/13/20151/13/2015 PART
DetailsAndy J. Long
Some sandy trackout to street and sidewalk from site is occuring. There is alot of sand on street from ACHD winter driving safety applications, so just need to sweep driveway apron and sidewalk.
No other violations. Vegetated buffer on slopes has remained intact.
General Inspection12/29/201412/29/201412/29/2014 PASS
DetailsAndy J. Long
WIP. No hillside erosion issues observed. There is a significant amount of sand from winter road safety activity - no trackout coming from site. Work ongoing on the interior.
General Inspection12/11/201412/11/201412/11/2014 PASS
DetailsEvan Jenkins
WIP: No ESC issues at this time
General Inspection11/26/201411/26/201412/1/2014 PASS
DetailsEvan Jenkins
Interior work only at time of ispection. Disturbed areas need final stabilization practices applied. no real esc issues at this time
General Inspection11/11/201411/11/201411/12/2014 PASS
DetailsAndy J. Long
House frame is up. No construction activity at time of inspection. No trackout to Pleasant Hill or other BMP violations observed. Approved.
General Inspection10/24/201410/24/201410/24/2014 PASS
DetailsAndy J. Long
No trackout, sediment runoff or other violations. WIP. No corrections
General Inspection9/25/20149/25/20149/25/2014 PASS
DetailsEvan Jenkins
Random Inspection8/25/20148/25/20148/25/2014PPART
DetailsAndy J. Long
No major ESC issues, but observed stockpile from a utility/sewer trench that is adjacent to sidewalk and unprotected. Advised RP/GC Chad Crocker to install containment BMP around stockpile or complete the backfill. He agreed to install wattle or move stockpile away from road.
General Inspection7/22/20147/22/20147/22/2014 PASS
DetailsEvan Jenkins
Site Preparation5/29/20145/30/20145/30/2014APASS
DetailsEvan Jenkins
Chad Phone #: ###-####